YBBP-315S Flameproof Variable-Frequency Motor

YBBP-315S is the 315S frame size (shaft height H = 315 mm) of the Shangli YBBP series of flameproof variable-frequency three-phase induction motors. It covers 45–110 kW in 2 / 4 / 6 / 8 / 10-pole versions with Ex marking Ex d I Mb / Ex d IIA T4 Gb / Ex d IIB T4 Gb / Ex d IIC T4 Gb, for operation on a VFD with constant torque at (3)5–50 Hz and constant power at 50–60 / 50–100 Hz, cooled by an independent axial-flow fan. The tables below list performance data and mounting dimensions for all 5 standard models on this frame. The catalogue writes the models as YBBP315S-2, YBBP315S-4, YBBP315S-6, YBBP315S-8, YBBP315S-10.

Series
YBBP Series Flameproof Variable-Frequency Three-Phase Induction Motors
Frame size / shaft height
315S / H = 315 mm
Output range
45–110 kW
Poles
2 / 4 / 6 / 8 / 10
Ex marking
Ex d I Mb / Ex d IIA T4 Gb / Ex d IIB T4 Gb / Ex d IIC T4 Gb
Rated voltage
380 V
Constant-torque range
(3)5–50 Hz
Constant-power range
50–60 / 50–100 Hz
Cooling
Independent axial-flow fan for the same cooling at any speed
Drive
Works with general-purpose VFDs from Chinese and international brands

Performance data

ModelOutput
kW
Output
HP
PolesSpeed
r/min
Current
A (380 V)
Rated torque
N·m
Efficiency
%
Power factor
cosφ
Noise
LwA dB(A)
Constant-torque
range Hz
Constant-power
range Hz
YBBP-315S-2110147.522975195350.194.00.91100(3)5–5050–60
YBBP-315S-4110147.541480201700.294.50.8896(3)5–5050–100
YBBP-315S-675100.66985142716.193.50.8694(3)5–5050–60
YBBP-315S-85573.88735111700.392.80.8194(3)5–5050–60
YBBP-315S-104560.31059099.6716.291.50.7592(3)5–5050–60

Rated values at 380 V, 50 Hz. A constant-torque range of (3)5–50 Hz means 5–50 Hz as standard and down to 3 Hz on request; the constant-power range is the speed range above 50 Hz. Rated torque is as given in the catalogue. Final values are those in the routine test report.

Mounting dimensions (mm)

Feet and shaft extension
Applies toABCHKDEFG
2-pole50840621631528651401858
4-pole and above50840621631528801702271
FF flange (IMB5 / IMB35 / IMV1)
FlangeMNPRαHoles × dia.T
FF600600550660022.5°8×Φ246.0

The YBBP series is developed from the YB3 series; feet, shaft extension and flange dimensions follow flameproof motors of the same frame size (YB3 / YBX3). The YBBP has an independent axial-flow fan at the non-drive end, so overall length L and height are larger than a standard flameproof motor and are confirmed on the approval drawing.

Outline drawing

Outline drawing of a flameproof motor in IMB3 foot mounting and IMB5 flange mounting with dimension codes A, B, C, H, K, M, N, P, D, E, F and G
Dimension codes for feet, shaft extension and flange. The YBBP has an independent axial-flow fan at the non-drive end, so its rear outline differs from the drawing.

Selection notes

  • Below 50 Hz the motor runs at constant torque: rated torque is available from (3)5 to 50 Hz, suitable for conveyors, extruders, mixers and hoisting equipment.
  • Above 50 Hz the motor runs at constant power: the range for this frame is 50–60 / 50–100 Hz and available torque falls as speed rises, suitable for high-speed fans and centrifuges.
  • An independent axial-flow fan keeps cooling constant at low speed; the fan needs its own power supply, so allow for it in the electrical design.
  • Choose the Ex marking for the site: Ex d I Mb for underground coal mines; Ex d IIA / IIB T4 Gb for IIA and IIB gases in petroleum and chemical plants; Ex d IIC T4 Gb where hydrogen or acetylene is present. The VFD is normally installed in a safe area; please give the drive brand, cable length and speed range in your enquiry.

Frequently asked questions

Can a standard flameproof motor run on a VFD? Why choose the

A standard flameproof motor is cooled by its own shaft fan, so airflow drops at low speed and temperature rises, with a risk of overheating in long low-frequency operation. The YBBP has an independent axial-flow fan that keeps cooling at rated torque even at 5 Hz, which makes it the better choice for continuous variable-speed duty.

What is the speed range of the

Constant torque from (3)5 to 50 Hz and constant power at 50–60 / 50–100 Hz; rated frequency 50 Hz.

How can I get CAD drawings and the Ex certificate for the

Complete the selection form at the bottom of this page with the model, Ex marking, speed range, VFD brand and file format required (DWG, STEP or PDF). Our sales team will send the drawings, certificate documents and a quotation.

Selection request

Tell us what you need. Our sales engineers confirm the configuration and send CAD drawings, technical documents and a quotation by email. Prices are not shown on the website because they depend on configuration and quantity.