Request a Quote

Shangli Motors · https://shanglimotors.com/motor-data/ybx4-132m.html

Motor Data & Drawings

YBX4-132M Flameproof Induction Motor

YBX4-132M is the 132M frame size (shaft height H = 132 mm) of the Shangli YBX4 series of super-premium efficiency flameproof three-phase induction motors. It covers 3–7.5 kW in 4 / 6 / 8-pole versions, with Ex marking Ex d IIB T4 Gb / Ex d IIC T4 Gb, IP55 enclosure and efficiency to China GB 18613-2020 grade 2. The tables below list performance data, mounting dimensions and outline drawings for all 4 standard models on this frame.

Series
YBX4 Series Super-Premium Efficiency Flameproof Three-Phase Induction Motors
Frame size / shaft height
132M / H = 132 mm
Output range
3–7.5 kW
Poles
4 / 6 / 8
Ex marking
Ex d IIB T4 Gb / Ex d IIC T4 Gb
Rated voltage
380 V (star up to 3 kW, delta above 3 kW); 660, 380/660, 400, 690 and 400/690 V available
Rated frequency
50 Hz (60 Hz available)
Enclosure
IP55
Insulation class
155 (F)
Duty
S1
Cooling
IC411
Efficiency
China GB 18613-2020 efficiency grade 2
Mounting
IMB3; IMB5, IMB35, IMV1, IMB14 and IMB34 available

Performance data

ModelOutput
kW
Output
HP
PolesSpeed
r/min
Current
A (380 V)
Torque
N·m
Efficiency
%
Power factor
cosφ
Locked-rotor torque
/ rated torque
Locked-rotor current
/ rated current
Breakdown torque
/ rated torque
Noise
LwA dB(A)
Weight
kg
YBX4-132M-47.510.14144015.249.792.60.812.09.52.371110
YBX4-132M1-645.469799.43989.50.722.082.16995
YBX4-132M2-65.57.4697912.853.790.50.722.082.169104
YBX4-132M-83487107.640.485.90.701.87.826495

Guaranteed values at 380 V, 50 Hz, duty S1. Rated torque is calculated as T = 9550 × P / n. Outputs in brackets are non-preferred ratings. Final values are those in the routine test report.

Mounting dimensions (mm)

Feet and shaft extension
Applies toABCHKDEFG
4-pole and above216178891321238801033
FF flange (IMB5 / IMB35 / IMV1)
FlangeMNPRαHoles × dia.T
FF265265230300045°4×Φ14.54.0
Overall dimensions
AAABACADBBHAHDHELA
602802652002301842049014
Overall length L
Applies toIMB3 / IMB5 / IMB35 etc.IMV1
4-pole and above570630
Cable entry thread
Single entryDouble entry
M30×2—

YBX3, YBX4 and YBX5 motors of the same frame size share the same mounting dimensions. Source: Shangli general motor catalogue. HE is the overall height of flange-mounted versions; overall length L varies slightly with terminal box and mounting arrangement and is confirmed on the approval drawing.

Outline drawings

Outline drawings of a YBX4 flameproof motor in IMB3 foot mounting and IMB5 flange mounting, with dimension codes A, B, C, H, K, AA, AB, AC, AD, BB, HA, HD, HE, L, M, N, P, R, T, LA and shaft key D, F, G
IMB3 (foot) and IMB5 (flange) outline drawings and shaft key section. Dimension codes match the tables above.
Outline drawings of a YBX4 flameproof motor in IMB35, IMB34, IMV1 and IMB14 mounting arrangements
IMB35 (foot and flange), IMB34 (foot and face flange), IMV1 (vertical flange) and IMB14 (face flange). IMB14 / IMB34 face flanges apply to frames 80–112 only.

Selection notes

  • Choose the Ex marking for the gas group at site: IIB covers IIB gases such as ethylene; sites with hydrogen, acetylene or other IIC gases need IIC. Temperature class T4 covers gases with an ignition temperature above 135 °C.
  • The standard version is for indoor use. State outdoor, anti-corrosion (W, WF1, WF2, F1, F2) or tropical (TH, TA, THW, TAW) conditions in your enquiry.
  • At 380 V, motors up to 3 kW are star-connected and larger motors delta-connected. Please state 660 V, 690 V, 380/660 V or 60 Hz in the selection form if required.
  • Outputs in brackets are non-preferred ratings; for the same output, choose the frame without brackets where possible. For variable-speed operation, give the speed range and load type so we can confirm the motor configuration.

Frequently asked questions

Can the YBX4-132M replace a YBX3 motor on the same frame?

Yes, for mounting. YBX3, YBX4 and YBX5 motors of the same frame size share the same mounting dimensions. The 132M frame has a shaft height of 132 mm; see the dimension tables above. Check the output, poles and Ex marking when replacing.

What is the Ex marking of the

Ex d IIB T4 Gb / Ex d IIC T4 Gb. Choose IIB or IIC for the gas group at site. The enclosure is IP55.

How can I get CAD drawings and the Ex certificate for the

Complete the selection form at the bottom of this page with the model, Ex marking, mounting arrangement and file format required (DWG, STEP or PDF). Our sales team will send the drawings, certificate documents and a quotation.

Selection request

Tell us what you need. Our sales engineers confirm the configuration and send CAD drawings, technical documents and a quotation by email. Prices are not shown on the website because they depend on configuration and quantity.

  • Click a row in the performance table to select that model.
  • CAD formats: DWG (2D), STEP (3D) or PDF.

We reply by email, usually within one working day.

WhatsApp: +8615523831294 +8615523831294 [email protected]

Home

Call

Back to Top

WhatsApp

Message