Request a Quote

Shangli Motors · https://shanglimotors.com/motor-data/ybx3-355l.html

Motor Data & Drawings

YBX3-355L Flameproof Induction Motor

YBX3-355L is the 355L frame size (shaft height H = 355 mm) of the Shangli YBX3 series of IE3 high-efficiency flameproof three-phase induction motors. It covers 160–315 kW in 2 / 4 / 6 / 8 / 10-pole versions, with Ex marking Ex d I Mb / Ex d IIA T4 Gb / Ex d IIB T4 Gb / Ex d IIC T4 Gb, IP55 enclosure and efficiency to China GB 18613-2012 grade 2 (IE3). The tables below list performance data, mounting dimensions and outline drawings for all 10 standard models on this frame.

Series
YBX3 Series IE3 High-Efficiency Flameproof Three-Phase Induction Motors
Frame size / shaft height
355L / H = 355 mm
Output range
160–315 kW
Poles
2 / 4 / 6 / 8 / 10
Ex marking
Ex d I Mb / Ex d IIA T4 Gb / Ex d IIB T4 Gb / Ex d IIC T4 Gb
Rated voltage
380, 660, 1140, 380/660 or 660/1140 V
Rated frequency
50 Hz
Enclosure
IP55 (IP56 and IP66 available)
Insulation class
155 (F)
Duty
S1
Cooling
IC411
Efficiency
China GB 18613-2012 grade 2, consistent with IE3 to IEC 60034-30
Mounting
IMB3, IMB5, IMB35, IMV1, IMB14, IMB34 and others

Performance data

ModelOutput
kW
Output
HP
PolesSpeed
r/min
Current
A (380 V)
Torque
N·m
Efficiency
%
Power factor
cosφ
Locked-rotor torque
/ rated torque
Locked-rotor current
/ rated current
Breakdown torque
/ rated torque
Noise
LwA dB(A)
Vibration classWeight
kg
YBX3-355L1-2(280)375.522980499.0897.395.80.891.87.12.21002.32040
YBX3-355L2-2315422.422980561.31009.595.80.891.87.12.21002.32060
YBX3-355L1-4(280)375.541488492.4179796.00.902.07.12.2952.32173
YBX3-355L2-4315422.441488553.92021.796.00.902.07.12.2952.32203
YBX3-355L1-62202956995404.42111.695.00.871.96.72.0922.32142
YBX3-355L2-6250335.36995459.62399.595.80.871.96.72.0922.32171
YBX3-355L1-8185248.18740364.32387.594.10.821.86.42.0902.31978
YBX3-355L2-8200268.28740388.22581.194.30.831.86.42.0902.32130
YBX3-355L1-10160214.610585333.3261293.50.781.36.02.0902.32086
YBX3-355L2-10185248.110585385.43020.193.50.781.36.02.0902.32130

Values at 380 V, 50 Hz, duty S1. Rated torque is calculated as T = 9550 × P / n. Weights are theoretical estimates for reference. Outputs in brackets are non-preferred ratings. Final values are those in the routine test report.

Mounting dimensions (mm)

Feet and shaft extension
Applies toABCHKDEFG
2-pole61063025435528751402067.5
4-pole and above61063025435528951702586
FF flange (IMB5 / IMB35 / IMV1)
FlangeMNPRαHoles × dia.T
FF740740680800022.5°8×Φ246.0
Overall dimensions
AAABACADBBHAHDHELA
120730710350700521080114525
Overall length L
Applies toIMB3 / IMB5 / IMB35 etc.IMV1
2-pole16151685
4-pole and above16451715
Cable entry thread
Single entryDouble entry
—M64×2

YBX3, YBX4 and YBX5 motors of the same frame size share the same mounting dimensions. Source: Shangli general motor catalogue. HE is the overall height of flange-mounted versions; overall length L varies slightly with terminal box and mounting arrangement and is confirmed on the approval drawing.

Outline drawings

Outline drawings of a YBX3 flameproof motor in IMB3 foot mounting and IMB5 flange mounting, with dimension codes A, B, C, H, K, AA, AB, AC, AD, BB, HA, HD, HE, L, M, N, P, R, T, LA and shaft key D, F, G
IMB3 (foot) and IMB5 (flange) outline drawings and shaft key section. Dimension codes match the tables above.
Outline drawings of a YBX3 flameproof motor in IMB35, IMB34, IMV1 and IMB14 mounting arrangements
IMB35 (foot and flange), IMB34 (foot and face flange), IMV1 (vertical flange) and IMB14 (face flange). IMB14 / IMB34 face flanges apply to frames 80–112 only.

Selection notes

  • Choose the Ex marking for the site: Ex d I Mb for underground coal mines with firedamp (methane); Ex d IIA T4 Gb or Ex d IIB T4 Gb for IIA and IIB explosive gas atmospheres other than coal mines; Ex d IIC T4 Gb where hydrogen or acetylene is present (the YBX3 IIC version has a different terminal box but the same outputs and mounting dimensions).
  • Service conditions: altitude up to 1000 m, ambient -20 to +40 °C; the basic version is for indoor use. Please state outdoor (W), indoor / outdoor humid tropical (TH / WTH), indoor / outdoor dry tropical (TA / WTA), indoor / outdoor tropical (T / WT) or outdoor medium anti-corrosion (WF1) in your enquiry.
  • Rated voltage 380, 660, 1140, 380/660 or 660/1140 V at 50 Hz; enclosure IP55, IP56 or IP66.
  • Outputs in brackets are non-preferred ratings; for the same output, choose the frame without brackets where possible. For higher efficiency the same frame can be supplied as YBX4 (IE4) or YBX5 (IE5) with unchanged mounting dimensions.

Frequently asked questions

Can the YBX3-355L replace a YB3 or YB2 flameproof motor?

YBX3 is derived from the YB3 series and has the same outputs and mounting dimensions as YB3. The 355L frame has a shaft height of 355 mm; see the dimension tables above. Check the output, poles and Ex marking when replacing.

Which Ex markings are available for the

The basic version is marked Ex d I Mb, Ex d IIA T4 Gb and Ex d IIB T4 Gb. For hydrogen or acetylene atmospheres a IIC version marked Ex d IIC T4 Gb is available. Enclosure IP55; IP56 and IP66 available.

How can I get CAD drawings and the Ex certificate for the

Complete the selection form at the bottom of this page with the model, Ex marking, mounting arrangement and file format required (DWG, STEP or PDF). Our sales team will send the drawings, certificate documents and a quotation.

Selection request

Tell us what you need. Our sales engineers confirm the configuration and send CAD drawings, technical documents and a quotation by email. Prices are not shown on the website because they depend on configuration and quantity.

  • Click a row in the performance table to select that model.
  • CAD formats: DWG (2D), STEP (3D) or PDF.

We reply by email, usually within one working day.

WhatsApp: +8615523831294 +8615523831294 [email protected]

Home

Call

Back to Top

WhatsApp

Message