YBFBX5-160M Flameproof and Dust Ignition-Proof Motor

YBFBX5-160M is the 160M frame size (shaft height H = 160 mm) of the Shangli YBFBX5 series of flameproof and dust ignition-proof high-efficiency three-phase induction motors. It covers 4–15 kW in 2 / 4 / 6 / 8-pole versions, with Ex marking Ex db IIC T4 Gb / Ex tb IIIC T130°C Db for both explosive gas and combustible dust atmospheres. The tables below list performance data, mounting dimensions and outline drawings for all 6 standard models on this frame.

Series
YBFBX5 Series Flameproof and Dust Ignition-Proof High-Efficiency Three-Phase Induction Motors
Frame size / shaft height
160M / H = 160 mm
Output range
4–15 kW
Poles
2 / 4 / 6 / 8
Ex marking
Ex db IIC T4 Gb / Ex tb IIIC T130°C Db
Rated voltage
380 V; at other voltages current I = IN × 380 / U
Rated frequency
50 Hz
Cooling
IC411
Efficiency
See performance data for each model
Mounting
IMB3, IMB5, IMB35, IMV1, IMB14, IMB34 and others

Performance data

ModelOutput
kW
Output
HP
PolesSpeed
r/min
Current
A (380 V)
Torque
N·m
Efficiency
%
Power factor
cosφ
Locked-rotor torque
/ rated torque
Locked-rotor current
/ rated current
Breakdown torque
/ rated torque
Noise
LpA dB(A)
Weight
kg
YBFBX5-160M1-21114.82293020.035.9940.892.29.52.367160
YBFBX5-160M2-21520.12293027.148.994.50.892.29.52.367176
YBFBX5-160M-41114.84146021.372.094.60.832.09.52.366176
YBFBX5-160M-67.510.1697015.773.892.90.782.182.162185
YBFBX5-160M1-845.487209.3153.189.40.731.97.92.060151
YBFBX5-160M2-85.57.4872012.573.090.40.742.08.12.060184

Values at 380 V, 50 Hz; efficiency applies at 75–100% load and noise is the no-load sound pressure level. At voltages other than 380 V, current I = IN × 380 / U and other values are unchanged. For 60 Hz motors, add 6 dB(A) to the no-load noise of 2-pole frames 200–355 and 5 dB(A) for other pole numbers. Final values are those in the routine test report.

Mounting dimensions (mm)

Feet and shaft extension
Applies toABCHKDEFG
All pole numbers on this frame25421010816014.5421101237
FF flange (IMB5 / IMB35 / IMV1)
FlangeMNPRαHoles × dia.T
FF300300250350045°4×Φ18.55.0
Overall dimensions
AAABACADBBHAHDHELA
703243202202582049052015
Overall length L
Applies toIMB3 / IMB5 / IMB35 etc.IMV1
All pole numbers on this frame730790
Cable entry thread
Single entryDouble entry
M36×2—

YBFBX5 motors share the mounting dimensions of YBX3, YBX4 and YBX5 flameproof motors of the same frame size. Source: Shangli general motor catalogue. HE is the overall height of flange-mounted versions; overall length L varies slightly with terminal box and mounting arrangement and is confirmed on the approval drawing.

Outline drawings

Outline drawings of a YBFBX5 flameproof and dust ignition-proof motor in IMB3 foot mounting and IMB5 flange mounting, with dimension codes A, B, C, H, K, AA, AB, AC, AD, BB, HA, HD, HE, L, M, N, P, R, T, LA and shaft key D, F, G
IMB3 (foot) and IMB5 (flange) outline drawings and shaft key section. Dimension codes match the tables above.
Outline drawings of a YBFBX5 flameproof and dust ignition-proof motor in IMB35, IMB34, IMV1 and IMB14 mounting arrangements
IMB35 (foot and flange), IMB34 (foot and face flange), IMV1 (vertical flange) and IMB14 (face flange). IMB14 / IMB34 face flanges apply to frames 80–112 only.

Selection notes

  • Ex marking Ex db IIC T4 Gb / Ex tb IIIC T130°C Db: the first covers explosive gas atmospheres in surface industry, including IIC gases such as acetylene, hydrogen and carbon disulphide; the second covers combustible dust, fibres and flyings. Choose this series where gas and dust may both be present, for example in flour, starch, plastics, resin and chemical raw-material processing.
  • For dust applications, state the dust type and its cloud and layer ignition temperatures so that the T130°C surface temperature limit can be checked against the site.
  • The standard version is for indoor use. Outdoor (W), indoor humid tropical (TH), outdoor humid tropical (WTH), outdoor tropical (WT) and outdoor medium anti-corrosion (WF1) versions are available; please state this in your enquiry.
  • Values are for 380 V, 50 Hz. At other voltages the rated current is I = IN × 380 / U. Please state 60 Hz or other voltages in the selection form.

Frequently asked questions

Can the YBFBX5-160M replace a YBX flameproof motor on the same frame?

Yes, for mounting. YBFBX5 motors share the mounting dimensions of YBX3, YBX4 and YBX5 flameproof motors of the same frame size. The 160M frame has a shaft height of 160 mm; see the dimension tables above. Choose YBFBX5 where combustible dust is present.

What is the difference between YBFBX5 and YBX5?

YBX5 is for explosive gas atmospheres only. YBFBX5 combines flameproof gas protection (Ex db IIC T4 Gb) with dust ignition protection by enclosure (Ex tb IIIC T130°C Db), for sites where gas and dust may both occur. Mounting dimensions are the same.

What is the Ex marking of the

Ex db IIC T4 Gb / Ex tb IIIC T130°C Db. Explosion protection complies with GB/T 3836.1-2021, GB/T 3836.2-2021 and GB/T 3836.31-2021.

How can I get CAD drawings and the Ex certificate for the

Complete the selection form at the bottom of this page with the model, the gas or dust present at site, mounting arrangement and file format required (DWG, STEP or PDF). Our sales team will send the drawings, certificate documents and a quotation.

Selection request

Tell us what you need. Our sales engineers confirm the configuration and send CAD drawings, technical documents and a quotation by email. Prices are not shown on the website because they depend on configuration and quantity.

  • Click a row in the performance table to select that model.
  • CAD formats: DWG (2D), STEP (3D) or PDF.

We reply by email, usually within one working day.

WhatsApp: +8615523831294 +8615523831294 zhang@shanglimotors.com

Home

Call

Back to Top

WhatsApp

Message